10 MW Steam Turbine Genset, Condensing- / Extraction- type
Year of manufacture 1978
Last Revision 1998
Operating hours total 136 000 Hours
Shut down 05/2001
Dismantled and completely refurbished 2004
Turbine Siemens
Type EENKS 32/36/80-3
Nominal Rating 10 000 kW
Design rating 6 800 kW
Inlet steam parameters normal . 65 barg, 515 deg C, 53,6 t/h
Inlet steam parameters max. 80 barg, 520 deg C, 69 t/h
Extraction 1 20,5 - 24 barg, 15,2 – 25 t/h
Extraction 2 12,5 - 14 barg, 23,4 - 35 t/h
Bleeding 0,8 – 1,7 barg, 1,8 – 6 t/h
Exhaust 0,1 bara, 22 – 26 t/h 46 deg C
Rotating speed 9 500 / 1 500 rpm
Condenser
Steam flow 26 t/h
Surface 185 m2
Cooling water temperature inlet 15 deg C
Cooling water flow 843 m3/h
Generator Siemens
Power rating 10 MW
Apparent power rating 12 500 kVA
Power factor 0,8
Voltage 6,3 kV, 50 Hz
|
|